Electricity calibration (DCV, ACV, DCI, ACI, Ω)

In our calibration laboratory, we can calibrate various DCV, ACV, DCI, ACI, Ω measuring devices (eg digital multimeters) and DCV, ACV, DCI, ACI, Ω reproducing sources (eg voltage source, decade resistor), calibrators. The more common measuring instruments and the range of measurements to which they can be calibrated are listed on this page. Calibration of these measuring instruments can be done even on site after consultation.

We also have multifunction "process" calibrator, which enables us to perform calibration of the production process sensor, gauge (even pressure gauge) on most production lines efficiently on the spot.


Contact us for more information about the possibilities!

Digital multimeters and other DCV, ACV, DCI, ACI, Ω measuring devices
(not accredited calibration)

Laboratory calibration:                 On site calibration:
  0 - 1000 V (DCV)                            0 - 1000 V (DCV)
            0 - 1000 V (50Hz – 1KHz ACV)      0 - 1000 V (50Hz – 1KHz ACV)     
                            0 - 11 A (DCI, ACI)                           0 - 11 A (DCI, ACI)                        
   0 - 100 GΩ                                        0 - 100 GΩ  
                
Digital multimeters (DMM) and other DCV, ACV, DCI, ACI, Ω measuring instruments (eg picoammeter) are calibrated by us using high-precision multifunction calibrators, based on the recommendation of EURAMET cg-15 (European Association of National Metrology Institutes).
Sources, calibrators and other DCV, ACV, DCI, ACI, Ω reproducing devices
(not accredited calibration)

Laboratory calibration:                         On site calibration:
                    0 - 1000 V (DCV)                                 0 - 1000 V (DCV)                  
         0 - 750 V (1Hz – 2MHz ACV)                 0 - 750 V (1Hz – 2MHz ACV)
0 - 2 A (DCI, ACI)                                       0 - 2 A (DCI, ACI)
0 - 1 GΩ                                                      0 - 1 GΩ  
     
Calibrators and other sources that reproduce DCV, ACV, DCI, ACI, Ω values (eg voltage source, resistance decade) can be calibrated within the measuring range below, based on recommendation of respectable national organisations. Calibration is performed with high precision multimeter and other reference standards.
Torque displays and tightening tool controllersŰ
(not accredited calibration)

Laboratory calibration:                           On site calibration:
           0 – 11 mV/V (0-9999,9 Nm)             0 – 11 mV/V (0-9999,9 Nm)

We calibrate torque displays and nutrunner controllers. The calibration is performed by elecrical simulator with high accuracy.
Transducer simulators
(not accredited calibration)


Laboratory calibration:                           On site calibration:
0 – 100 mV/V                                                  0 – 100 mV/V